The One-Stop Guide to Data Center Cooling: Keeping Your IT Infrastructure Chill

Industrial Chillers

Data centers are the vertebral column of our connected world.

These facilities house powerful IT equipment that generates enormous amounts of heat during daily operations

This trapped heat can damage expensive hardware and cause system failures.

For this, data centers rely on modern cooling systems that comply with the equipment standards and increase efficiency.

Data Centre Cooling
Data Centre Cooling
Data Centre Cooling

What is Data Center Cooling?

Types of Data Center Cooling Methods

Air Cooling Methods

Liquid Cooling Methods

Air Cooling Methods:

Room Cooling

CRAC/CRAH Systems

Free Air Cooling

Uses cooler outside air to reduce mechanical cooling needs
Requires filtration systems to maintain air quality
Offers significant energy and cost savings
May involve occasional temperature fluctuations

Close-Coupled Cooling

In-Row Cooling

Positions cooling units between server cabinets
Available in chilled water or direct expansion varieties
Creates horizontal airflow pattern
Compatible with hot aisle containment

Rear-Door Heat Exchangers (RDHx)

Attaches directly to the backs of server racks
Cools hot exhaust air immediately upon exit from servers
Available in two main configurations:
Passive RDHx: Uses server fans to move air, supports 20-30kW per rack
Active RDHx: Includes additional fans, supports up to 50kW per cabinet

offers space-efficient cooling for high-density applications
Minimizes hot air recirculation in the data center

Liquid Cooling Methods

Direct-to-Chip Cooling

This entails:

Routes liquid coolant through cold plates attached to specific components
Targets the highest heat-generating parts of servers
Transfers heat via conduction between electronics and cold plates
Requires supplementary air cooling for remaining components

Immersion Cooling

Fully submerged servers in dielectric fluid
Prevents electrical shorts while providing superior heat transfer
Available in two variations:
Single-phase: Pumps fluid through tanks and external heat exchangers
Two-phase: Fluid boils and condenses within a self-contained system
Supports the highest-density deployments

As we are observing a drastic increase in computing demands, data center cooling keeps focusing on more-efficient and energy-saving technologies. But, how will you choose the right cooling system? Here is what you need to consider.

Factors to Consider for Data Center Cooling

These factors determine the data center cooling capacity for better operational efficiency.

IT density:

Higher equipment density requires an advanced industrial cooling system.

Containment measures:

Install doors and walls for air flow direction

Humidity control:

The infrastructure must consider humidity control for air cooling

Size:

The size of the IT facility determines the type of cooling capacity and setup.

Investment

The investment or cost of ownership along with maintenance and operational expenses must be considered.

Sustainability

Consider sustainability factors like carbon footprint, eco-friendly cooling technologies, and energy consumption.

IT facilities can benefit a lot from installing modern data center cooling systems. Choosing one can be daunting due to a lack of experience. This is where industrial cooling experts come into the picture.

Get the Best Data Center Cooling Solutions from Tempcon

Industrial chiller experts like Tempcon have decades of experience in designing data center cooling solutions. With us, your IT facility will benefit in the following ways:
Server reliability improvement

Achieve the perfect balance of data center performance, reliability and sustainability with Tempcon. Contact us for further information.

FAQ

How is liquid cooling different from traditional cooling systems?

Liquid cooling does not introduce pollutants and condensation, unlike air-cooling methods. This method of data center cooling is more efficient and sustainable.

Which is the most efficient data center cooling method?

Free air cooling is considered the most efficient in terms of investment, energy consumption, etc.

Which data center cooling solution is ideal for heavy IT operations?

Direct-to-chip cooling targets chip-level cooling and reduces energy consumption by 90%. However, this technology requires a substantial investment.

Still have more questions?

Contact Us

Trusted By Leading Companies

Call Us

+91 7044597958 (Sales)

+91 8777366568 (Service)

+91 33 24426216(Service)

Send us an email:
info@tempcon.co.in

Request a Quote



Tempcon is much more than a manufacturer of cooling and temperature control systems. We are technical advisors with the expertise to recognize the best solution- in terms of productivity, efficiency, environmental impact. Innovation creates new opportunity & being able to customise our cooling solutions is what makes us unique!

Get In Touch

F.R.S 4/5 & 6, Kasba Industrial Estate(PH-1), E.M. Bypass(East), Kolkata - 700107, India.

+91 33 24426216 (Office)

+91 33 24422359 (Office)

+91 90381 27722 (Sales)

+91 70445 97958 (Sales)

+91 87773 66568 (Service)

+91 74394 82790 (Service)

info@tempcon.co.in

Chiller Machine

Tempcon is much more than a manufacturer of cooling and temperature control systems. We are technical advisors with the expertise to recognize the best solution- in terms of productivity, efficiency, environmental impact. Innovation creates new opportunity & being able to customise our cooling solutions is what makes us unique!

40 YEARS

of Legacy

8777366568